CVE-2026-22552 ePower epower.ie Missing Authentication for Critical Function
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: yes · technical impact: total
Description
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
Upgrade path
1 package: 0 fixed, 1 with no fix yet.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| epower.ie | = All versions; All versions | No fix listed | No fix yet |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| epower.ie | = All versions | No fix listed |
| epower.ie | All versions | No fix listed |
References
- epower.ie product
- www.cisa.gov us-government-resource
- github.com product