Skip to content

CVE-2026-34021 Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay

HighCVSS 8.6 EPSS 0.20%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
Proof of concept public · automatable: no · technical impact: total

Description

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

Upgrade path

1 package: 0 fixed.

PackageAffectedFixed inStatus
Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) = Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 No fix listed Versions listed

Affected products

ProductAffected versionsFixed in
Wertheim GmbH Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) = Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 No fix listed

References