CVE-2026-44107 Exposed Reboot via Modbus

HighCVSS 8.7 EPSS 0.56%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: yes · technical impact: partial

Description

A reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Service attack.

Upgrade path

4 packages: 4 fixed.

PackageAffectedFixed inStatus
Phoenix Contact CHARX SEC-3000 >= 1.0.0, < 1.9.1 1.9.1 Fixed
Phoenix Contact CHARX SEC-3050 >= 1.0.0, < 1.9.1 1.9.1 Fixed
Phoenix Contact CHARX SEC-3100 >= 1.0.0, < 1.9.1 1.9.1 Fixed
Phoenix Contact CHARX SEC-3150 >= 1.0.0, < 1.9.1 1.9.1 Fixed

Affected products

ProductAffected versionsFixed in
Phoenix Contact CHARX SEC-3150 >= 1.0.0, < 1.9.1 1.9.1
Phoenix Contact CHARX SEC-3100 >= 1.0.0, < 1.9.1 1.9.1
Phoenix Contact CHARX SEC-3050 >= 1.0.0, < 1.9.1 1.9.1
Phoenix Contact CHARX SEC-3000 >= 1.0.0, < 1.9.1 1.9.1