CVE-2026-58115 A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1Y...
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: yes · technical impact: total
Description
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.
This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
Upgrade path
4 packages: 0 fixed, 4 partially fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) | < V4.3.4-1; All versions | V4.3.4-1 | Partially fixed |
| Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) | < V4.3.4-1; All versions | V4.3.4-1 | Partially fixed |
| Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) | < V4.3.4-1; All versions | V4.3.4-1 | Partially fixed |
| Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) | < V4.3.4-1; All versions | V4.3.4-1 | Partially fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) | < V4.3.4-1 | V4.3.4-1 |
| Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) | All versions | No fix listed |
| Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) | < V4.3.4-1 | V4.3.4-1 |
| Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) | All versions | No fix listed |
| Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) | < V4.3.4-1 | V4.3.4-1 |
| Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) | All versions | No fix listed |
| Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) | < V4.3.4-1 | V4.3.4-1 |
| Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) | All versions | No fix listed |
References
- cert-portal.siemens.com
- ENISA EUVD EUVD-2026-56119 third-party-advisory