CVE-2026-81818 Flowintel Organization Administrator Can Reset Full Administrator Password and Escalate Privileges

HighCVSS 8.6 EPSS 0.39%
Published
Updated
Exploit status
No public exploit known
CISA SSVC
No known exploitation · automatable: no · technical impact: total

Description

Affected versions of Flowintel contain an authorization flaw in the administrative user-edit API.

The existing authorization check correctly prevented an organization administrator from editing users in another organization, but it did not prevent them from editing a full administrator within their own organization. As a result, an org admin could modify that full administrator account, including changing its password. The upstream commit explicitly describes the issue as:

“Org admin can change the password of a full admin in the same organization.”

The fix adds a higher-privilege boundary check:

if user_to_edit.is_admin(): return ... 403

so organization administrators can no longer modify full administrator accounts.

Version impacted >=3.3.0

Upgrade path

1 package: 1 fixed.

PackageAffectedFixed inStatus
flowintel <= 3.3.0 after 3.3.0 Fixed

Affected products

ProductAffected versionsFixed in
flowintel <= 3.3.0 No fix listed

References