CVE-2026-88850 WAGO: Missing Authorization for PROFIBUS Configuration in WBM
HighCVSS 7.2
EPSS 0.49%
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: partial
Description
The Web-Based Management (WBM) authorization model does not properly enforce permissions for all PROFIBUS configuration operations. A low-privileged remote attacker can abuse an exposed configuration function to modify root-owned PROFIBUS parameters, including device addressing and SSA settings. This allows unauthorized changes to fieldbus-related configuration and violates the intended privilege boundaries within the management interface.
Upgrade path
11 packages: 11 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| WAGO 0750-811x-xxxx-xxxx | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0750-821x-xxx-xxx | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0751-9x01 | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0752-8303-8000-0002 | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-340x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-420x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-430x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-520x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-530x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-620x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
| WAGO 0762-630x-8000-000x | >= 1.0.0, < 4.10.0; >= 1.0.0, < 4.10.0 (70) | 4.10.0, 4.10.0 (70) | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| WAGO 0751-9x01 | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0750-811x-xxxx-xxxx | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0750-821x-xxx-xxx | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-420x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-430x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-520x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-530x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-620x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-630x-8000-000x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0752-8303-8000-0002 | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0762-340x | >= 1.0.0, < 4.10.0 | 4.10.0 |
| WAGO 0751-9x01 | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0750-811x-xxxx-xxxx | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0750-821x-xxx-xxx | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-420x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-430x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-520x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-530x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-620x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-630x-8000-000x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0752-8303-8000-0002 | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
| WAGO 0762-340x | >= 1.0.0, < 4.10.0 (70) | 4.10.0 (70) |
References
- www.certvde.com
- ENISA EUVD EUVD-2026-132980 third-party-advisory
- nvd.nist.gov