CVE-2026-95109 Cortex-A7 module data validation checks only the first address of a caller-supplied range
- Published
- Updated
- Exploit status
- No public exploit known
- CISA SSVC
- No known exploitation · automatable: no · technical impact: total
Description
The Cortex-A7 MMU Modules port validates a caller-supplied buffer by translating one address — the first byte. The common Module Manager hands its range check the module instance, the start address and the complete byte size; the Cortex-A7 implementation discarded the instance and the size and asked the MMU a single question about the start.
A memory-protected module therefore passed any range whose first byte was user-readable, however far the rest of it reached. Privileged dispatch code then read or wrote the whole range. Because every protected-module dispatcher that consumes a buffer or an extra-parameter array goes through this one macro, the defect is not in any individual service: it is in the primitive all of them rely on.
Upgrade path
1 package: 1 fixed.
| Package | Affected | Fixed in | Status |
|---|---|---|---|
| Eclipse Foundation Eclipse ThreadX | >= 6.1, <= 6.5.1.202602a | after 6.5.1.202602a | Fixed |
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Eclipse Foundation Eclipse ThreadX | >= 6.1, <= 6.5.1.202602a | No fix listed |
References
- github.com
- ENISA EUVD EUVD-2026-105145 third-party-advisory