In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of comm...
Vendor
AVEVA vulnerabilities
91 published CVES affecting AVEVA, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 91
- Critical
- 21
- High
- 48
- Medium
- 18
- Low
- 4
- Unscored
- 0
- CISA KEV
- 0
Products
- edge 14
- aveva edge 11
- clearscada 9
- system platform 9
- Process Optimization 7
- AVEVA System Platform 6
- suitelink 6
- edna enterprise data historian 5
- indusoft web studio 5
- Application Server 4
- Batch Management 4
- Historian 4
- InTouch 4
- intouch machine edition 2014 4
- PI Server 4
- Pipeline Integrity Monitor 4
- Communication Drivers Pack 3
- manufacturing execution system 3
- mobile operator 3
- Telemetry Server 3
- wonderware intouch access anywhere 3
- work tasks 3
- communication drivers 2
- Edge (formerly known as Indusoft Web Studio) 2
- enterprise licensing 2
- Enterprise Licensing (formerly known as License Manager) 2
- intouch 2017 2
- InTouch Access Anywhere 2
- Manufacturing Execution System (formerly known as Wonderware MES) 2
- Mobile Operator (formerly known as IntelaTrac Mobile Operator Rounds) 2
Latest AVEVA CVEs
Newest publication first · page 4 of 4
-
HighCVSS 7.5 EPSS 1.6%
-
HighCVSS 7.5 EPSS 1.0%
Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the S...
-
MediumCVSS 5.3 EPSS 0.55%
An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly.
-
CriticalCVSS 9.8 EPSS 2.4%
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
-
HighCVSS 8.8 EPSS 0.96%
A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The client request may be forged from a different site. This will allow an external site to access internal RDP systems on behalf of the currently...
-
LowCVSS 2.1 EPSS 0.37%
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
-
LowCVSS 3.3 EPSS 0.77%
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
-
MediumCVSS 5.0 EPSS 2.4%
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guess...
-
LowCVSS 2.1 EPSS 0.37%
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to o...
-
MediumCVSS 5.0 EPSS 1.0%
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
-
MediumCVSS 5.0 EPSS 1.6%
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
-
LowCVSS 3.5 EPSS 1.3%
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
-
MediumCVSS 6.8 EPSS 1.5%
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013...
-
MediumCVSS 4.3 EPSS 1.2%
DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service (resource consumption) via IP packets containing errors that trigger event-journ...
-
MediumCVSS 4.3 EPSS 2.5%
Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
-
HighCVSS 10.0 EPSS 7.5%
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.