An unauthenticated attacker can trick a local user into executing arbitrary commands by opening a deliberately manipulated project file with an affected engineering tool. These arbitrary commands are executed in the user context.
Vendor
beckhoff vulnerabilities
23 published CVES affecting beckhoff, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 23
- Critical
- 5
- High
- 10
- Medium
- 8
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Products
- twincat 10
- TwinCAT/BSD 4
- IPC Diagnostics package 3
- embedded pc images 2
- ipc diagnostics 2
- TwinCAT 2 2
- TwinCAT 3.1 2
- TwinCAT Components featuring Automation Device Specification (ADS) communication 2
- authelia-bhf 1
- authelia-bhf of TwinCAT/BSD 1
- bk9000 firmware 1
- cx9020 1
- ipc diagnostics ua server 1
- MDP package 1
- TE1000 | TwinCAT 3 Enineering 1
- tf6100 1
- tf6100 firmware 1
- ts6100 firmware 1
- twincat c++ 1
- twincat driver 1
- TwinCat Driver for Intel 8254x (Tcl8254x.sys) 1
- TwinCat Driver for Intel 8255x (Tcl8255x.sys) 1
- twincat extended automation runtime 1
- twincat opc ua server 1
- TwinCAT Package Manager 1
- twincat packet manager 1
- TwinCat XAR 3.1 1
Latest beckhoff CVEs
Newest publication first
-
HighCVSS 7.8
-
MediumCVSS 6.5
A local user with administrative access rights can enter specialy crafted values for settings at the user interface (UI) of the TwinCAT Package Manager which then causes arbitrary OS commands to be executed.
-
CVE-2024-41176 Beckhoff: Local Denial of Service issue in package MDP included in TwinCAT/BSD
PublishedHighCVSS 7.3The MPD package included in TwinCAT/BSD allows an authenticated, low-privileged local attacker to induce a Denial-of-Service (DoS) condition on the daemon and execute code in the context of user “root” via a crafted HTTP request.
-
MediumCVSS 5.5
The IPC-Diagnostics package included in TwinCAT/BSD is vulnerable to a local denial-of-service attack by a low privileged attacker.
-
HighCVSS 7.3
The IPC-Diagnostics package in TwinCAT/BSD is susceptible to improper input neutralization by a low-privileged local attacker.
-
HighCVSS 7.8
The IPC-Diagnostics package included in TwinCAT/BSD is vulnerable to a local authentication bypass by a low privileged attacker.
-
MediumCVSS 4.7
The package authelia-bhf included in Beckhoffs TwinCAT/BSD is prone to an open redirect that allows a remote unprivileged attacker to redirect a user to another site. This may have limited impact to integrity and does solely affect anthelia-bhf the Beckhoff fork of authelia.
-
CVE-2021-34594 Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server
PublishedMediumCVSS 6.5TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system.
-
CriticalCVSS 9.8
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE sid...
-
CVE-2020-12526 BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server
PublishedMediumCVSS 5.3TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA serv...
-
HighCVSS 7.3
The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation register...
-
MediumCVSS 5.3
Beckhoff's TwinCAT RT network driver for Intel 8254x and 8255x is providing EtherCAT functionality. The driver implements real-time features. Except for Ethernet frames sent from real-time functionality, all other Ethernet frames sent through the driver are not padded if their pa...
-
HighCVSS 7.5
A Denial-of-Service vulnerability exists in BECKHOFF Ethernet TCP/IP Bus Coupler BK9000. After an attack has occurred, the device's functionality can be restored by rebooting.
-
CriticalCVSS 9.8
Beckhoff Embedded Windows PLCs through 3.1.4024.0, and Beckhoff Twincat on Windows Engineering stations, allow an attacker to achieve Remote Code Execution (as SYSTEM) via the Beckhoff ADS protocol.
-
HighCVSS 7.5
When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior).
-
HighCVSS 7.5
When a Beckhoff TwinCAT Runtime receives a malformed UDP packet, the ADS Discovery Service shuts down. Note that the TwinCAT devices are still performing as normal. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior).
-
CriticalCVSS 9.1
Beckhoff TwinCAT supports communication over ADS. ADS is a protocol for industrial automation in protected environments. ADS has not been designed to achieve security purposes and therefore does not include any encryption algorithms because of their negative effect on performance...
-
MediumCVSS 5.9
Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password...
-
HighCVSS 7.8
Kernel drivers in Beckhoff TwinCAT 3.1 Build 4022.4, TwinCAT 2.11 R3 2259, and TwinCAT 3.1 lack proper validation of user-supplied pointer values. An attacker who is able to execute code on the target may be able to exploit this vulnerability to obtain SYSTEM privileges.
-
CriticalCVSS 9.1
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components might allow remote attackers to obtain access via the (1) Windows CE Remote Configuration Tool, (2) CE Remote Display service, or (3) TELNET service.
-
CriticalCVSS 9.1
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components do not restrict the number of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
-
HighCVSS 9.0
Beckhoff IPC Diagnostics before 1.8 does not properly restrict access to functions in /config, which allows remote attackers to cause a denial of service (reboot or shutdown), create arbitrary users, or possibly have unspecified other impact via a crafted request, as demonstrated...
-
MediumCVSS 5.0 EPSS 49.7% Framework module PoC
Beckhoff TwinCAT 2.11.0.2004 and earlier allows remote attackers to cause a denial of service via a crafted request to UDP port 48899, which triggers an out-of-bounds read.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.