An information disclosure vulnerability was discovered in Bosch IP camera devices allowing an unauthenticated attacker to retrieve information (like capabilities) about the device itself and network settings of the device, disclosing possibly internal network settings if the devi...
Product
Bosch cpp6 firmware vulnerabilities
7 published CVES affecting Bosch cpp6 firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 7
- Critical
- 2
- High
- 1
- Medium
- 4
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest Bosch cpp6 firmware CVEs
Newest publication first
-
MediumCVSS 5.3 EPSS 0.60%
-
CVE-2021-23849 Cross Site Request Forgery (CSRF) vulnerability in web based management interface
PublishedHighCVSS 8.8 EPSS 0.49%A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a maliciou...
-
MediumCVSS 6.1 EPSS 0.56%
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
-
CriticalCVSS 9.1 EPSS 1.4%
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware...
-
CriticalCVSS 9.8 EPSS 0.86%
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs.
-
MediumCVSS 6.1 EPSS 0.56%
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user.
-
MediumCVSS 4.9 EPSS 0.83%
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.