Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by...
Product
Dell idrac7 firmware vulnerabilities
9 published CVES affecting Dell idrac7 firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 9
- Critical
- 2
- High
- 4
- Medium
- 3
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest Dell idrac7 firmware CVEs
Newest publication first
-
CriticalCVSS 9.8 EPSS 3.8%
-
MediumCVSS 4.3 EPSS 0.88%
Dell EMC iDRAC7 versions prior to 2.65.65.65, iDRAC8 versions prior to 2.70.70.70 and iDRAC9 versions prior to 3.36.36.36 contain an improper authorization vulnerability. A remote authenticated malicious iDRAC user with low privileges may potentially exploit this vulnerability to...
-
CriticalCVSS 9.8 EPSS 4.2%
Dell EMC iDRAC6 versions prior to 2.92, iDRAC7/iDRAC8 versions prior to 2.61.60.60, and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22 and 3.23.23.23 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may potentially exploit this...
-
MediumCVSS 6.8 EPSS 0.42%
Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 contain an improper error handling vulnerability. An unauthenticated attacker with physical access to the system could potentially exploit this vulnerability to get access to the u-boot shell.
-
HighCVSS 8.8 EPSS 0.94%
Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22, and 3.23.23.23 contain a privilege escalation vulnerability. An authenticated malicious iDRAC user with operator privileges could potentially exploit a permissions...
-
CVE-2018-1244 iDRAC7/iDRAC8/iDrac9 contains a command injection vulnerability in the SNMP agent.
PublishedHighCVSS 8.8 EPSS 3.3%Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to exe...
-
HighCVSS 7.5 EPSS 1.8%
Dell EMC iDRAC6, versions prior to 2.91, iDRAC7/iDRAC8, versions prior to 2.60.60.60 and iDRAC9, versions prior to 3.21.21.21, contain a weak CGI session ID vulnerability. The sessions invoked via CGI binaries use 96-bit numeric-only session ID values, which makes it easier for r...
-
HighCVSS 8.8 EPSS 1.8%
Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection.
-
MediumCVSS 4.3 EPSS 1.6%
Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorM...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.