A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs.
Product
emerson x-stream enhanced xefd firmware vulnerabilities
7 published CVES affecting emerson x-stream enhanced xefd firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 7
- Critical
- 1
- High
- 3
- Medium
- 3
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest emerson x-stream enhanced xefd firmware CVEs
Newest publication first
-
HighCVSS 7.5 EPSS 1.4%
-
CriticalCVSS 9.8 EPSS 1.8%
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code.
-
HighCVSS 7.5 EPSS 0.45%
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
-
MediumCVSS 6.1 EPSS 0.70%
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information.
-
MediumCVSS 6.1 EPSS 0.64%
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page an...
-
MediumCVSS 5.3 EPSS 0.90%
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistent cookies where the session cookie attribute is not properly invalidated, allowing an attacker to intercept the cookies and gain access to s...
-
HighCVSS 7.5 EPSS 1.3%
Emerson Rosemount X-STREAM Gas AnalyzerX-STREAM enhanced XEGP, XEGK, XEFD, XEXF – all revisions, The affected products are vulnerable to improper authentication for accessing log and backup data, which could allow an attacker with a specially crafted URL to obtain access to sensi...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.