Skip to content

Product

Gallagher Controller 6000 and Controller 7000 vulnerabilities

7 published CVES affecting Gallagher Controller 6000 and Controller 7000, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
7
Critical
0
High
0
Medium
7
Low
0
Unscored
0
CISA KEV
0

Latest Gallagher Controller 6000 and Controller 7000 CVEs

Newest publication first

  1. MediumCVSS 4.6 EPSS 0.32%

    Use of Multiple Resources with Duplicate Identifier (CWE-694) in the Controller 6000 and Controller 7000 Platforms could allow an attacker with physical access to HBUS communication cabling to perform a Denial-of-Service attack against HBUS connected devices, require a device reb...

  2. MediumCVSS 4.6 EPSS 0.23%

    Incorrect Calculation of Buffer Size (CWE-131) in the Controller 6000 and Controller 7000 OSDP message handling, allows an attacker with physical access to Controller wiring to instigate a reboot leading to a denial of service. This issue affects: Controller 6000 and Controller 7...

  3. MediumCVSS 6.5 EPSS 0.34%

    Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabl...

  4. MediumCVSS 6.1 EPSS 0.28%

    Improper Neutralization of Input During Web Page Generation (CWE-79) in the Controller 6000 and Controller 7000 diagnostic webpage allows an attacker to modify Controller configuration during an authenticated Operator's session. This issue affects: Controller 6000 and Controller...

  5. MediumCVSS 6.3 EPSS 0.17%

    External Control of File Name or Path (CWE-73) in the Controller 6000 and Controller 7000 allows an attacker with local access to the Controller to perform arbitrary code execution. This issue affects: 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to v...

  6. MediumCVSS 6.8 EPSS 0.31%

    External Control of Critical State Data (CWE-642) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authenticated user to modify device I/O connections leading to unexpected behavior that in some circumstances could compromise site physical security co...

  7. MediumCVSS 4.6 EPSS 0.19%

    Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access. This issue affects: Gallagher C...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.