When performing an online tag generation to devices which communicate using the ControlLogix protocol, a machine-in-the-middle, or a device that is not configured correctly, could deliver a response leading to unrestricted or unregulated resource allocation. This could cause a de...
Vendor
ge vulnerabilities
129 published CVES affecting ge, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 129
- Critical
- 35
- High
- 56
- Medium
- 38
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Products
- cimplicity 12
- intelligent platforms proficy hmiscada cimplicity 10
- industrial gateway server 7
- ge communicator 6
- intelligent platforms proficy historian 6
- intelligent platforms proficy process systems with cimplicity 6
- intelligent platforms proficy real-time information portal 6
- multilin b30 firmware 6
- multilin b90 firmware 6
- multilin c30 firmware 6
- multilin c60 firmware 6
- multilin c70 firmware 6
- multilin c95 firmware 6
- multilin d30 firmware 6
- multilin d60 firmware 6
- multilin f35 firmware 6
- multilin f60 firmware 6
- multilin g30 firmware 6
- multilin g60 firmware 6
- multilin l30 firmware 6
- multilin l60 firmware 6
- multilin l90 firmware 6
- multilin m60 firmware 6
- multilin n60 firmware 6
- multilin t35 firmware 6
- multilin t60 firmware 6
- UR family 6
- ifix 5
- inet 900 firmware 5
- inet ii 900 firmware 5
Latest ge CVEs
Newest publication first · page 1 of 6
-
MediumCVSS 5.9
-
HighCVSS 7.5
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
-
CriticalCVSS 9.1
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
-
HighCVSS 7.3
General Electric MiCOM S1 Agile is vulnerable to an attacker achieving code execution by placing malicious DLL files in the directory of the application.
-
HighCVSS 7.8
GE CIMPLICITY 2023 is by a process control vulnerability, which could allow a local attacker to insert malicious configuration files in the expected web server execution path to escalate privileges and gain full control of the HMI software.
-
CriticalCVSS 9.8
All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, sta...
-
HighCVSS 7.8
ToolboxST prior to version 7.10 is affected by a deserialization vulnerability. An attacker with local access to an HMI or who has conducted a social engineering attack on an authorized operator could execute code in a Toolbox user's context through the deserialization of an untr...
-
CriticalCVSS 9.8 EPSS 3.4%
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue res...
-
CriticalCVSS 9.1 EPSS 3.4%
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue res...
-
CriticalCVSS 9.8
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software.
-
CriticalCVSS 9.8
The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.
-
CriticalCVSS 9.8
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
-
HighCVSS 7.5 EPSS 0.63%
An unauthorized user with network access and the decryption key could decrypt sensitive data, such as usernames and passwords.
-
HighCVSS 8.1
An unauthorized user could possibly delete any file on the system.
-
MediumCVSS 6.5
An unauthorized user could be able to read any file on the system, potentially exposing sensitive information.
-
MediumCVSS 6.5
An unauthorized user could alter or write files with full control over the path and content of the file.
-
CVE-2022-46732 CVE-2022-46732
PublishedCriticalCVSS 9.8Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
-
CriticalCVSS 9.8
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
-
CriticalCVSS 9.8
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. The debug port accessible via TCP (a qconn service) lacks access control.
-
HighCVSS 7.5
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888.
-
MediumCVSS 4.6 EPSS 0.19%
Certain General Electric Renewable Energy products store cleartext credentials in flash memory. This affects iNET and iNET II before 8.3.0.
-
CriticalCVSS 9.8 EPSS 0.31%
Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.
-
CriticalCVSS 9.8 EPSS 0.77%
Certain General Electric Renewable Energy products have a hidden feature for unauthenticated remote access to the device configuration shell. This affects iNET and iNET II before 8.3.0.
-
CriticalCVSS 9.1 EPSS 0.67%
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
-
CriticalCVSS 9.8 EPSS 0.37%
Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.