Skip to content

Vendor

ge vulnerabilities

129 published CVES affecting ge, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
129
Critical
35
High
56
Medium
38
Low
0
Unscored
0
CISA KEV
0
Atom feed of ge alerts

Products

Latest ge CVEs

Newest publication first · page 4 of 6

  1. HighCVSS 7.8 EPSS 0.42%

    GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.

  2. HighCVSS 7.5 EPSS 2.6%

    GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vuln...

  3. MediumCVSS 4.8 EPSS 0.30%

    Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX produc...

  4. HighCVSS 7.6 EPSS 0.99%

    A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.

  5. CriticalCVSS 9.8 EPSS 4.8%

    Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.

  6. HighCVSS 7.5 EPSS 3.5%

    In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow...

  7. CriticalCVSS 9.8 EPSS 3.0%

    GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

  8. CriticalCVSS 9.8 EPSS 1.9%

    GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affe...

  9. CriticalCVSS 9.8 EPSS 1.9%

    GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

  10. CriticalCVSS 9.8 EPSS 4.7%

    GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devi...

  11. CriticalCVSS 9.8 EPSS 3.8%

    A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.

  12. CriticalCVSS 9.8 EPSS 5.9%

    An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote atta...

  13. MediumCVSS 6.8 EPSS 0.75%

    A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.

  14. MediumCVSS 5.4 EPSS 1.2%

    Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.

  15. CriticalCVSS 9.8 EPSS 1.3%

    A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versi...

  16. MediumCVSS 6.7 EPSS 0.37%

    An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if...

  17. CriticalCVSS 9.8 EPSS 3.2%

    General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interfac...

  18. HighCVSS 10.0 EPSS 3.1%

    Absolute path traversal vulnerability in the download feature in FileDownloadServlet in GE Digital Energy MDS PulseNET and MDS PulseNET Enterprise before 3.1.5 allows remote attackers to read or delete arbitrary files via a full pathname.

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.