gpsd versions 2.90 to 3.17 and microjson versions 1.0 to 1.3, an open source project, allow a stack-based buffer overflow, which may allow remote attackers to execute arbitrary code on embedded platforms via traffic on Port 2947/TCP or crafted JSON inputs.
Vendor
ICS-CERT vulnerabilities
93 published CVES affecting ICS-CERT, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 93
- Critical
- 21
- High
- 48
- Medium
- 23
- Low
- 1
- Unscored
- 0
- CISA KEV
- 0
Products
- Moxa IKS, EDS 9
- CX-Supervisor 7
- LCDS Laquis SCADA 7
- Omron CX-Supervisor 6
- NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. 4
- Advantech WebAccess HMI Designer 3
- Delta Electronics WPLSoft 3
- Dräger Infinity Delta 3
- IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors 3
- Omron CX-One 3
- PR100088 Modbus gateway 3
- WECON LeviStudioU 3
- ABB IP GATEWAY 2
- AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update 2
- BeaconMedæs TotalAlert Scroll Medical Air Systems web application 2
- Beckhoff TwinCAT 2
- CNCSoft with ScreenEditor 2
- DeltaV 2
- Niagara AX Framework and Niagara 4 Framework 2
- VGo Robot 2
- ABB CP400 Panel Builder TextEditor 2.0 1
- ABB eSOMS 1
- ABB SREA-01 and SREA-50 1
- Advantech WebAccess Versions 8.1 and prior. 1
- BD FACSLyric 1
- BeaconMedaes TotalAlert Scroll Medical Air Systems web application 1
- Beckhoff TwinCAT PLC products 1
- Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001 1
- Cscape 1
- Delta Industrial Automation CNCSoft 1
Latest ICS-CERT CVEs
Newest publication first · page 1 of 4
-
HighCVSS 8.8 EPSS 2.7%
-
MediumCVSS 6.1 EPSS 1.1%
Moxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script.
-
CriticalCVSS 9.8 EPSS 1.7%
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
-
HighCVSS 8.8 EPSS 1.2%
Cross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
-
MediumCVSS 6.5 EPSS 2.4%
Moxa IKS and EDS allow remote authenticated users to cause a denial of service via a specially crafted packet, which may cause the switch to crash.
-
CriticalCVSS 9.8 EPSS 5.0%
Several buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
-
HighCVSS 8.8 EPSS 2.6%
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Ga...
-
CriticalCVSS 9.8 EPSS 2.7%
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
-
CriticalCVSS 9.1 EPSS 2.5%
Moxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot.
-
HighCVSS 7.5 EPSS 1.7%
Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
-
HighCVSS 7.5 EPSS 1.2%
Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device.
-
HighCVSS 7.5 EPSS 3.3%
Pangea Communications Internet FAX ATA all Versions 3.1.8 and prior allow an attacker to bypass user authentication using a specially crafted URL to cause the device to reboot, which may be used to cause a continual denial-of-service condition.
-
MediumCVSS 5.5 EPSS 1.1%
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.
-
HighCVSS 7.8 EPSS 1.7%
Cscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
-
HighCVSS 7.8 EPSS 1.6%
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
-
CriticalCVSS 9.8 EPSS 17.3% Public exploit
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
-
HighCVSS 7.5 EPSS 13.9% Public exploit
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. An unauthenticated remote user could use a specially crafted database connection configuration file to execute an arbitrary proce...
-
HighCVSS 7.8 EPSS 1.6%
A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
-
HighCVSS 7.8 EPSS 2.1%
Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilit...
-
HighCVSS 7.8 EPSS 1.9%
Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based...
-
MediumCVSS 5.0 EPSS 0.83%
When CX-Supervisor (Versions 3.42 and prior) processes project files and tampers with the value of an offset, an attacker can force the application to read a value outside of an array.
-
HighCVSS 7.3 EPSS 1.2%
An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
-
HighCVSS 7.2 EPSS 0.59%
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
-
CriticalCVSS 9.1 EPSS 1.2%
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
-
CriticalCVSS 9.8 EPSS 1.2%
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.