NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device is vulnerable to several cross-site scripting attacks, allowing a remote attacker to run arbitrary code on the device.
Vendor
ICS-CERT vulnerabilities
93 published CVES affecting ICS-CERT, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 93
- Critical
- 21
- High
- 48
- Medium
- 23
- Low
- 1
- Unscored
- 0
- CISA KEV
- 0
Products
- Moxa IKS, EDS 9
- CX-Supervisor 7
- LCDS Laquis SCADA 7
- Omron CX-Supervisor 6
- NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. 4
- Advantech WebAccess HMI Designer 3
- Delta Electronics WPLSoft 3
- Dräger Infinity Delta 3
- IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors 3
- Omron CX-One 3
- PR100088 Modbus gateway 3
- WECON LeviStudioU 3
- ABB IP GATEWAY 2
- AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update 2
- BeaconMedæs TotalAlert Scroll Medical Air Systems web application 2
- Beckhoff TwinCAT 2
- CNCSoft with ScreenEditor 2
- DeltaV 2
- Niagara AX Framework and Niagara 4 Framework 2
- VGo Robot 2
- ABB CP400 Panel Builder TextEditor 2.0 1
- ABB eSOMS 1
- ABB SREA-01 and SREA-50 1
- Advantech WebAccess Versions 8.1 and prior. 1
- BD FACSLyric 1
- BeaconMedaes TotalAlert Scroll Medical Air Systems web application 1
- Beckhoff TwinCAT PLC products 1
- Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001 1
- Cscape 1
- Delta Industrial Automation CNCSoft 1
Latest ICS-CERT CVEs
Newest publication first · page 3 of 4
-
MediumCVSS 6.1 EPSS 0.98%
-
HighCVSS 8.8 EPSS 0.66%
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. A cross-site request forgery condition can occur, allowing an attacker to change passwords of the device remotely.
-
HighCVSS 7.5 EPSS 1.6%
NetComm Wireless G LTE Light Industrial M2M Router (NWL-25) with firmware 2.0.29.11 and prior. The device allows access to configuration files and profiles without authenticating the user.
-
CriticalCVSS 9.8 EPSS 10.5%
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is le...
-
CriticalCVSS 9.8 EPSS 6.7%
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
-
CriticalCVSS 9.1 EPSS 0.51%
Beckhoff TwinCAT supports communication over ADS. ADS is a protocol for industrial automation in protected environments. ADS has not been designed to achieve security purposes and therefore does not include any encryption algorithms because of their negative effect on performance...
-
MediumCVSS 5.9 EPSS 0.42%
Beckhoff TwinCAT 3 supports communication over ADS. ADS is a protocol for industrial automation in protected environments. This protocol uses user configured routes, that can be edited remotely via ADS. This special command supports encrypted authentication with username/password...
-
CriticalCVSS 9.8 EPSS 68.3% Framework module Public exploit PoC
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network pack...
-
HighCVSS 7.8 EPSS 2.7% Public exploit
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the aff...
-
CriticalCVSS 9.8 EPSS 1.4%
In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
-
CriticalCVSS 9.8 EPSS 2.5%
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
-
HighCVSS 8.8 EPSS 0.64%
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
-
HighCVSS 8.2 EPSS 0.37%
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a...
-
MediumCVSS 5.3 EPSS 0.41%
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a...
-
HighCVSS 8.3 EPSS 0.40%
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a...
-
CriticalCVSS 9.8 EPSS 1.3%
In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.
-
CriticalCVSS 9.8 EPSS 2.5%
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP...
-
HighCVSS 7.5 EPSS 3.5%
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow...
-
MediumCVSS 5.5 EPSS 2.0%
Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data..
-
MediumCVSS 6.5 EPSS 0.64%
In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker may be able to capture firmware updates through the adjacent network.
-
HighCVSS 8.8 EPSS 2.1%
In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker on an adjacent network could perform command injection.
-
HighCVSS 7.8 EPSS 1.6%
Advantech WebAccess 8.1 and earlier contains a DLL hijacking vulnerability which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code.
-
HighCVSS 8.8 EPSS 2.6%
WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution.
-
HighCVSS 8.8 EPSS 2.7%
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
-
HighCVSS 8.8 EPSS 2.7%
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.