An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as u...
Product
INEA me-rtu firmware vulnerabilities
7 published CVES affecting INEA me-rtu firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 7
- Critical
- 4
- High
- 1
- Medium
- 2
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest INEA me-rtu firmware CVEs
Newest publication first
-
MediumCVSS 6.5 EPSS 1.3%
-
CriticalCVSS 9.8 EPSS 1.9%
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak creden...
-
CriticalCVSS 9.8 EPSS 2.3%
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the...
-
CriticalCVSS 9.8 EPSS 2.1%
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial ins...
-
MediumCVSS 5.4 EPSS 43.2%
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variab...
-
HighCVSS 7.5 EPSS 40.9% Public exploit
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as...
-
CriticalCVSS 9.8 EPSS 57.4% Public exploit
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user s...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.