A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer.
Product
MZ Automation GmbH lib60870 vulnerabilities
3 published CVES affecting MZ Automation GmbH lib60870, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 3
- Critical
- 0
- High
- 1
- Medium
- 2
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest MZ Automation GmbH lib60870 CVEs
Newest publication first
-
MediumCVSS 6.9 EPSS 0.46%
-
MediumCVSS 6.9 EPSS 0.46%
A crafted IEC 60870-5-104 I-frame with a declared object count exceeding what fits in the ASDU body causes InformationObject_ParseObjectAddress to read one byte past the end of the heap-allocated message buffer.
-
HighCVSS 8.8 EPSS 0.43%
The affected product is vulnerable to an Out-of-bounds read, which may allow an attacker to crash the parsing process and cause a denial of service.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.