Skip to content

Vendor

Philips vulnerabilities

128 published CVES affecting Philips, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
128
Critical
11
High
63
Medium
46
Low
8
Unscored
0
CISA KEV
2
Atom feed of Philips alerts

Products

Latest Philips CVEs

Newest publication first · page 4 of 6

  1. MediumCVSS 6.8 EPSS 0.40%

    In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to b...

  2. HighCVSS 7.2 EPSS 1.4%

    Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Versio...

  3. HighCVSS 7.2 EPSS 0.69%

    Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Versio...

  4. LowCVSS 3.4 EPSS 0.34%

    In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system...

  5. HighCVSS 8.8 EPSS 1.9%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.

  6. CriticalCVSS 9.8 EPSS 3.8%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input...

  7. MediumCVSS 6.1 EPSS 1.3%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.

  8. HighCVSS 8.8 EPSS 0.87%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.

  9. HighCVSS 8.8 EPSS 0.57%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could...

  10. MediumCVSS 5.3 EPSS 1.7%

    Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally...

  11. MediumCVSS 6.2 EPSS 0.41%

    In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow th...

  12. MediumCVSS 6.7 EPSS 0.45%

    In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges...

  13. HighCVSS 7.8 EPSS 0.39%

    In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbi...

  14. HighCVSS 7.8 EPSS 0.91%

    Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applica...

  15. HighCVSS 8.2 EPSS 0.37%

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a...

  16. MediumCVSS 5.3 EPSS 0.41%

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.