An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escala...
Vendor
progea vulnerabilities
8 published CVES affecting progea, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 8
- Critical
- 0
- High
- 6
- Medium
- 2
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Products
Latest progea CVEs
Newest publication first
-
MediumCVSS 6.7 EPSS 0.41%
-
HighCVSS 7.8 EPSS 0.70%
An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious...
-
CVE-2014-0778 Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor
PublishedMediumCVSS 5.0 EPSS 1.3%TCPUploader module listens on Port 10651/TCP for incoming connections. Exploitation of this vulnerability could allow a remote unauthenticated user access to release OS version information. While this is a minor vulnerability, it represents a method for further network reconnaiss...
-
HighCVSS 7.8 EPSS 2.8%
The OPC server in Progea Movicon before 11.3 allows remote attackers to cause a denial of service (out-of-bounds read and memory corruption) via a crafted HTTP request.
-
HighCVSS 10.0 EPSS 9.8% PoC
Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long request.
-
HighCVSS 10.0 EPSS 15.2% PoC
Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location.
-
HighCVSS 10.0 EPSS 16.2% PoC
Heap-based buffer overflow in Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a negative Content-Length field.
-
HighCVSS 10.0 EPSS 7.6% Public exploit
TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.