8 published CVES affecting schneider-electric interactive graphical scada system data server, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
8
Critical
4
High
4
Medium
0
Low
0
Unscored
0
CISA KEV
0

Latest schneider-electric interactive graphical scada system data server CVEs

Newest publication first

  1. HighCVSS 7.5 EPSS 1.3%

    A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

  2. HighCVSS 7.5 EPSS 19.3%

    A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

  3. HighCVSS 7.5 EPSS 18.2%

    A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

  4. CriticalCVSS 9.8 EPSS 44.6%

    A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Ser...

  5. CriticalCVSS 9.8 EPSS 3.5%

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when...

  6. CriticalCVSS 9.8 EPSS 3.5%

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attack...

  7. CriticalCVSS 9.8 EPSS 2.2%

    A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.