Skip to content

Product

Schneider Electric EcoStruxure Process Expert vulnerabilities

10 published CVES affecting Schneider Electric EcoStruxure Process Expert, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
10
Critical
3
High
6
Medium
1
Low
0
Unscored
0
CISA KEV
0

Latest Schneider Electric EcoStruxure Process Expert CVEs

Newest publication first

  1. HighCVSS 7.0 EPSS 0.16%

    CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.

  2. HighCVSS 8.5 EPSS 0.24%

    CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit trail data and the other acting as server managing client request) that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when an a...

  3. HighCVSS 8.1 EPSS 0.32%

    CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.

  4. CriticalCVSS 9.8 EPSS 1.1%

    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process...

  5. CriticalCVSS 9.8 EPSS 0.87%

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Co...

  6. CriticalCVSS 9.8 EPSS 0.92%

    A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (fo...

  7. HighCVSS 7.8 EPSS 26.1%

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file...

  8. MediumCVSS 5.9 EPSS 0.66%

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Aff...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.