Skip to content

Product

Sciener kontrol lux firmware vulnerabilities

3 published CVES affecting Sciener kontrol lux firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
3
Critical
2
High
1
Medium
0
Low
0
Unscored
0
CISA KEV
0

Latest Sciener kontrol lux firmware CVEs

Newest publication first

  1. CVE-2023-7006 CVE-2023-7006

    Published
    CriticalCVSS 9.1 EPSS 0.79%

    The unlockKey character in a lock using Sciener firmware can be brute forced through repeated challenge requests, compromising the locks integrity.

  2. CVE-2023-7009 CVE-2023-7009

    Published
    HighCVSS 8.2 EPSS 0.37%

    Some Sciener-based locks support plaintext message processing over Bluetooth Low Energy, allowing unencrypted malicious commands to be passed to the lock. These malicious commands, less then 16 bytes in length, will be processed by the lock as if they were encrypted communication...

  3. CVE-2023-7017 CVE-2023-7017

    Published
    CriticalCVSS 9.8 EPSS 0.43%

    Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing a...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.