Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoi...
Vendor
Shenzhen Tenda Technology Co., Ltd. vulnerabilities
25 published CVES affecting Shenzhen Tenda Technology Co., Ltd., from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 25
- Critical
- 2
- High
- 13
- Medium
- 9
- Low
- 1
- Unscored
- 0
- CISA KEV
- 0
Products
Latest Shenzhen Tenda Technology Co., Ltd. CVEs
Newest publication first
-
HighCVSS 7.1 EPSS 0.46%
-
MediumCVSS 5.1 EPSS 0.19%
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a cross-site request forgery (CSRF) vulnerability in the web-based administrative interface. The interface does not implement anti-CSRF protections, allowing an attacker to induce an authenticated administrato...
-
MediumCVSS 5.1 EPSS 0.40%
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response...
-
MediumCVSS 5.1 EPSS 0.40%
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and...
-
HighCVSS 8.6 EPSS 3.3%
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the comman...
-
HighCVSS 8.2 EPSS 0.31%
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
-
MediumCVSS 5.1 EPSS 0.22%
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a log...
-
MediumCVSS 6.8 EPSS 0.20%
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, respo...
-
MediumCVSS 5.1 EPSS 0.34%
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a v...
-
HighCVSS 7.1 EPSS 0.45%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) implement an insecure Cross-Origin Resource Sharing (CORS) policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: * in combination with Access-Control-Allow-Cred...
-
LowCVSS 2.1 EPSS 0.34%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced response...
-
MediumCVSS 5.1 EPSS 0.19%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) lack cross-site request forgery (CSRF) protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests t...
-
MediumCVSS 5.1 EPSS 0.30%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when admi...
-
HighCVSS 7.1 EPSS 0.30%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials.
-
MediumCVSS 4.8 EPSS 0.19%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized acces...
-
CriticalCVSS 9.2 EPSS 0.78%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.
-
HighCVSS 8.7 EPSS 0.64%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain an authorization flaw in the user management API that allows a low-privileged authenticated user to change the administrator account password. By sending a crafted request directly to the backe...
-
HighCVSS 8.2 EPSS 0.49%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) disclose sensitive account credentials in cleartext within HTTP responses generated by the maintenance interface. Because the management interface is accessible over unencrypted HTTP by default, creden...
-
CriticalCVSS 9.3 EPSS 0.78%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain...
-
HighCVSS 8.7 EPSS 0.55%
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected e...
-
HighCVSS 8.7 EPSS 2.8% Public exploit
Tenda D151 and D301 routers contain an unauthenticated configuration download vulnerability that allows remote attackers to retrieve router configuration files. Attackers can send a request to /goform/getimage endpoint to download configuration data including admin credentials wi...
-
HighCVSS 8.3 EPSS 1.2%
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50.
-
HighCVSS 8.3 EPSS 0.89%
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoubleL2tpConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
-
HighCVSS 8.3 EPSS 0.89%
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoublePppoeConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
-
HighCVSS 8.3 EPSS 0.89%
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromAdvSetLanip(overflow arg:lanMask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.