A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions...
Product
Siemens simatic wincc open architecture vulnerabilities
8 published CVES affecting Siemens simatic wincc open architecture, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 8
- Critical
- 2
- High
- 1
- Medium
- 5
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest Siemens simatic wincc open architecture CVEs
Newest publication first
-
MediumCVSS 6.7 EPSS 0.46%
-
MediumCVSS 5.9 EPSS 0.98%
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. S...
-
CriticalCVSS 9.8 EPSS 34.3%
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TC...
-
CriticalCVSS 9.1 EPSS 2.2%
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. Thi...
-
MediumCVSS 5.0 EPSS 2.1%
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.
-
MediumCVSS 5.0 EPSS 3.5%
Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.
-
HighCVSS 7.5 EPSS 5.3%
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.
-
MediumCVSS 5.0 EPSS 1.7%
Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.