The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curv...
Product
Siemens SIMOTION vulnerabilities
4 published CVES affecting Siemens SIMOTION, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 4
- Critical
- 0
- High
- 4
- Medium
- 0
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Latest Siemens SIMOTION CVEs
Newest publication first
-
HighCVSS 7.5 EPSS 73.2% Public exploit
-
HighCVSS 7.5 EPSS 1.4%
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
-
HighCVSS 7.1 EPSS 0.91%
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
-
HighCVSS 7.1 EPSS 1.1%
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.