Skip to content

Product

Siemens sinamics sl150 firmware vulnerabilities

11 published CVES affecting Siemens sinamics sl150 firmware, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
11
Critical
4
High
7
Medium
0
Low
0
Unscored
0
CISA KEV
0

Latest Siemens sinamics sl150 firmware CVEs

Newest publication first

  1. CriticalCVSS 9.8 EPSS 1.7%

    The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Produ...

  2. CriticalCVSS 9.8 EPSS 1.5%

    SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution o...

  3. HighCVSS 7.5 EPSS 1.8%

    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4"...

  4. HighCVSS 7.5 EPSS 2.6%

    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4"...

  5. CriticalCVSS 9.8 EPSS 2.6%

    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4"...

  6. HighCVSS 7.5 EPSS 1.8%

    A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4"...

  7. CriticalCVSS 9.8 EPSS 5.3%

    A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (...

  8. HighCVSS 7.5 EPSS 1.4%

    The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an...

  9. HighCVSS 7.1 EPSS 1.1%

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.