Skip to content

Product

tenda ac1206 vulnerabilities

18 published CVES affecting tenda ac1206, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
18
Critical
11
High
6
Medium
1
Low
0
Unscored
0
CISA KEV
0

Latest tenda ac1206 CVEs

Newest publication first

  1. CriticalCVSS 9.3 EPSS 2.0%

    A vulnerability was detected in Tenda AC1206 15.03.06.23. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit...

  2. HighCVSS 8.7 EPSS 1.8%

    A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been rated as critical. This issue affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclo...

  3. HighCVSS 8.7 EPSS 1.8%

    A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been declared as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm. The manipulation leads to buffer overflow. The attack can be initiated remotely. The exploit has been disc...

  4. HighCVSS 8.7 EPSS 2.2%

    A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possi...

  5. MediumCVSS 5.3 EPSS 14.5%

    A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has...

  6. CriticalCVSS 9.8 EPSS 0.99%

    Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVir...

  7. CriticalCVSS 9.8 EPSS 0.99%

    Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setacc...

  8. CriticalCVSS 9.8 EPSS 0.97%

    Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpee...

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.