A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
Vendor
ABB vulnerabilities
265 published CVES affecting ABB, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 265
- Critical
- 48
- High
- 136
- Medium
- 74
- Low
- 7
- Unscored
- 0
- CISA KEV
- 0
Products
- ASPECT®-Enterprise 60
- MATRIX Series 60
- NEXUS Series 60
- aspect-ent-12 firmware 29
- aspect-ent-2 firmware 29
- aspect-ent-256 firmware 29
- aspect-ent-96 firmware 29
- matrix-11 firmware 29
- matrix-216 firmware 29
- matrix-232 firmware 29
- matrix-264 firmware 29
- matrix-296 firmware 29
- nexus-2128 firmware 29
- nexus-2128-a firmware 29
- nexus-2128-f firmware 29
- nexus-2128-g firmware 29
- nexus-264 firmware 29
- nexus-264-a firmware 29
- nexus-264-f firmware 29
- nexus-264-g firmware 29
- nexus-3-2128 firmware 29
- nexus-3-264 firmware 29
- aspect enterprise 21
- eSOMS 13
- ABB Ability™ Symphony® Plus Operations 9
- symphony + historian 9
- symphony + operations 9
- ABB Ability™ Symphony® Plus Historian 8
- advabuild 7
- FLXEON 7
Latest ABB CVEs
Newest publication first · page 8 of 11
-
CriticalCVSS 9.8 EPSS 0.54%
-
HighCVSS 7.5 EPSS 2.6%
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an...
-
HighCVSS 8.6 EPSS 1.6%
An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart th...
-
CriticalCVSS 9.8 EPSS 1.2%
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
-
CriticalCVSS 9.8 EPSS 1.1%
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present...
-
HighCVSS 8.8 EPSS 3.1%
In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines.
-
CriticalCVSS 9.8 EPSS 1.5%
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a con...
-
HighCVSS 7.0 EPSS 0.28%
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
-
CriticalCVSS 9.8 EPSS 1.9%
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
-
HighCVSS 8.8 EPSS 1.4%
Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data.
-
HighCVSS 7.8 EPSS 0.43%
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
-
HighCVSS 8.8 EPSS 1.5%
An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges.
-
CriticalCVSS 9.8 EPSS 1.4%
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running the...
-
CriticalCVSS 9.8 EPSS 1.4%
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
-
MediumCVSS 5.5 EPSS 0.32%
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
-
CriticalCVSS 9.8 EPSS 70.9% Framework module
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
-
HighCVSS 7.8 EPSS 0.34%
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Infor...
-
CVE-2020-8488 ABB System 800xA Inter process communication vulnerability - 800xA Batch Management
PublishedHighCVSS 7.8 EPSS 0.41%Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing...
-
CVE-2020-8487 ABB System 800xA Inter process communication vulnerability - System 800xA Base
PublishedHighCVSS 7.8 EPSS 0.33%Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
-
HighCVSS 7.8 EPSS 0.33%
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
-
CVE-2020-8485 ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300
PublishedHighCVSS 7.8 EPSS 0.34%Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
-
HighCVSS 7.8 EPSS 0.34%
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
-
LowCVSS 3.3 EPSS 0.34%
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affect...
-
CriticalCVSS 9.8 EPSS 1.9%
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0...
-
HighCVSS 7.8 EPSS 0.37%
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ En...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.