The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.
Vendor
Delta Electronics vulnerabilities
230 published CVES affecting Delta Electronics, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 230
- Critical
- 64
- High
- 134
- Medium
- 32
- Low
- 0
- Unscored
- 0
- CISA KEV
- 1
Products
- DIAEnergie 69
- InfraSuite Device Master 31
- CNCSoft-G2 15
- DIAScreen 14
- DIALink 12
- DOPSoft 12
- ispsoft 9
- CNCSoft 8
- ASDA-Soft 5
- DIAView 5
- wplsoft 5
- Delta UFC500 4
- DVP-12SE11T 4
- COMMGR 3
- Delta Industrial Automation DOPSoft 3
- DOPSoft 2 3
- DRASimuCAD 3
- pmsoft 3
- TPEditor 3
- CNCSoft ScreenEditor 2
- cncsoft-b 2
- CNCSoft-B DOPSoft 2
- Delta Industrial Automation TPEditor 2
- DTM Soft 2
- DTN Soft 2
- Automation TPEditor 1
- CNCSoft-B v1.0.0.4 DOPSoft 1
- CNCSoft-G2 DOPSoft 1
- Delta Industrial Automation PMSoft 1
- Delta Robot Automation Studio (DRAS) 1
Latest Delta Electronics CVEs
Newest publication first · page 1 of 10
-
HighCVSS 8.7 EPSS 0.24%
-
HighCVSS 8.7 EPSS 0.19%
Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace, and log in to read...
-
HighCVSS 8.4 EPSS 0.15%
The shipped WebUI template database retains the factory default passwords for all five account types in cleartext. Defaults are identical across devices and were unchanged on the tested unit.
-
MediumCVSS 5.3 EPSS 0.19%
HTTP basic auth enforces no retry limit or backoff. Combined with the default service password, the keyspace is exhaustible.
-
CriticalCVSS 9.8 EPSS 0.59%
ASDA-Soft Stack-based Buffer Overflow Vulnerability
-
CriticalCVSS 9.8 EPSS 1.5%
Delta Electronics DIAView has Command Injection vulnerability.
-
CriticalCVSS 9.8 EPSS 0.57%
Delta Electronics DIAView has multiple vulnerabilities.
-
HighCVSS 8.1 EPSS 0.53%
Delta Electronics DIAView has multiple vulnerabilities.
-
CriticalCVSS 9.8 EPSS 0.34%
DVP-12SE11T - Out-of-bound memory write Vulnerability
-
HighCVSS 7.5 EPSS 0.32%
DVP-12SE11T - Denial of Service Vulnerability
-
CriticalCVSS 9.8 EPSS 0.34%
DVP-12SE11T - Authentication Bypass via Partial Password Disclosure
-
CriticalCVSS 9.8 EPSS 0.32%
DVP-12SE11T - Password Protection Bypass
-
HighCVSS 7.2 EPSS 0.34%
DVP-12SE - Modbus/TCP Cleartext Transmission of Sensitive Information
-
HighCVSS 7.5 EPSS 0.22%
Delta Electronics DVP15MC11T lacks proper validation of the modbus/tcp packets and can lead to denial of service.
-
HighCVSS 7.8 EPSS 0.20%
ASDA-Soft Stack-based Buffer Overflow Vulnerability
-
HighCVSS 7.8 EPSS 0.20%
ASDA-Soft Stack-based Buffer Overflow Vulnerability
-
MediumCVSS 6.8 EPSS 0.19%
Delta Electronics DIAScreen lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
MediumCVSS 6.8 EPSS 0.16%
Delta Electronics DIAScreen lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
MediumCVSS 6.8 EPSS 0.16%
Delta Electronics DIAScreen lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
MediumCVSS 6.8 EPSS 0.16%
Delta Electronics DIAScreen lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
HighCVSS 7.8 EPSS 0.16%
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
HighCVSS 7.8 EPSS 0.30%
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
HighCVSS 7.3 EPSS 18.8%
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
-
CriticalCVSS 10.0 EPSS 1.3%
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
-
MediumCVSS 5.8 EPSS 0.16%
Delta Electronics DIAView has an authentication bypass vulnerability.
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.