Skip to content

Product

Delta Electronics DIALink vulnerabilities

12 published CVES affecting Delta Electronics DIALink, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).

Total
12
Critical
1
High
5
Medium
6
Low
0
Unscored
0
CISA KEV
0

Latest Delta Electronics DIALink CVEs

Newest publication first

  1. MediumCVSS 4.8 EPSS 12.3%

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter comment of the API events, which may allow an attacker to remotely execute code.

  2. HighCVSS 7.8 EPSS 0.26%

    Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.

  3. MediumCVSS 4.8 EPSS 11.4%

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an attacker to remotely execute code.

  4. HighCVSS 7.8 EPSS 0.23%

    Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.

  5. MediumCVSS 4.8 EPSS 0.64%

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely execute code.

  6. HighCVSS 7.8 EPSS 0.51%

    The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.

  7. MediumCVSS 4.8 EPSS 0.64%

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remotely execute code.

  8. HighCVSS 7.8 EPSS 0.18%

    Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.

  9. MediumCVSS 5.9 EPSS 0.57%

    Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.

  10. MediumCVSS 4.8 EPSS 0.64%

    Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacker to remotely execute code.

Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.