Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send su...
Vendor
Dräger vulnerabilities
16 published CVES affecting Dräger, from public sources (CVE.org, NVD, CISA KEV, FIRST EPSS, OSV).
- Total
- 16
- Critical
- 0
- High
- 13
- Medium
- 3
- Low
- 0
- Unscored
- 0
- CISA KEV
- 0
Products
- Infinity Acute Care System 2
- Infinity Delta 2
- Infinity Delta XL 2
- Infinity Kappa 2
- Infinity M300 2
- Protector Software 2
- SC 6002XL 2
- SC 7000 2
- SC6802XL 2
- SC8000 2
- SC90000 XL 2
- Standalone Infinity M540 patient monitor 2
- Atlan A350 1
- CC-Vision Basic 1
- CC-Vision E-Cal 1
- Core 1
- Infinity Explorer C700 1
- M540 Converter Service 1
- Perseus A500 1
- Zeus IE 1
- Zeus RS C500 1
Latest Dräger CVEs
Newest publication first
-
HighCVSS 7.1 EPSS 0.20%
-
CVE-2021-4481 Dräger Protector Software Local Privilege Escalation via Insecure File Permissions
PublishedHighCVSS 8.3 EPSS 0.11%Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the hos...
-
CVE-2021-4480 Dräger Protector Software Local Privilege Escalation via Insecure File Permissions
PublishedHighCVSS 8.3 EPSS 0.11%Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges. Attackers can replace binaries or loaded modules on the hos...
-
HighCVSS 7.0 EPSS 0.17%
Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can exploit the unprotecte...
-
HighCVSS 8.7 EPSS 0.28%
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the ho...
-
HighCVSS 8.8 EPSS 0.16%
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-o...
-
MediumCVSS 6.3 EPSS 0.24%
Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed...
-
CVE-2021-4478 Dräger CC-Vision Basic and CC-Vision E-Cal Out-of-Bounds Write via Malicious GDT File
PublishedHighCVSS 8.3 EPSS 0.12%Dräger CC-Vision Basic before 7.5.3 and Dräger CC-Vision E-Cal before 7.2.5.0 contain an out-of-bounds write vulnerability when loading .gdt files. A crafted .gdt file can trigger a buffer overflow during file parsing, allowing an attacker to crash the application or execute mali...
-
HighCVSS 7.1 EPSS 0.18%
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail sta...
-
MediumCVSS 6.3 EPSS 0.24%
Dräger Perseus A500 software versions 2.00 through 2.02 contains an improper input handling vulnerability that allows external attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can overload t...
-
HighCVSS 7.2 EPSS 0.19%
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A lo...
-
HighCVSS 7.1 EPSS 0.19%
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attack...
-
HighCVSS 8.8 EPSS 0.13%
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service co...
-
CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure
PublishedMediumCVSS 5.3 EPSS 0.20%Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired networ...
-
HighCVSS 8.6 EPSS 0.12%
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating...
-
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
PublishedHighCVSS 7.1 EPSS 0.41%Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient moni...
Sources: CVE.org, NVD, CISA KEV, FIRST EPSS, OSV and public exploit-reference metadata. Product matching comes from the published CVE records. A proof-of-concept means public code exists; it is not evidence of exploitation.